Extech 校準器 accommodate 聲級計 with 0.5” and 1” microphones. The Calibrator’s die-cast aluminum housing is built for ruggedness and durability. The 407744 provides a 94dB校準 output signal while the 407766 provides both 94dB and 114dB outputs. This 專業校準儀, with proper care, will provide years of safe reliable service.
| Output signals |
407744: 94dB |
| Output signal accuracy | 407744: ± 0.5dB; 407766: ± 0.5dB (94dB), ±0.8dB (114dB) |
| Accuracy of output signal frequency | ± 5% |
| Compatible microphones sizes | 0.5” and 1” microphones |
| Total Harmonic Distortion (THD) | <2%@94dB, <5%@114dB (407766) |
| Operating temperature | 32 to 122oF (0 to 50oC) |
| Power supply | Two (2) 9V batteries |
| Power consumption | Approx. 10mA DC |
| Battery check | Status LED |
| 方面 | 2.2” diameter x 5.7” length (50 x 145mm) |
| 重量 | 0.75 lbs. (340g) |
| Output signal frequency | 1KHz sine wave |
Description
1. ½” Microphone adaptor
2. 407766: OFF-94dB-114dB switch, 407744: OFF-BATTERY TEST-94dB switch
3. 407766: POWER-ON / LOW-BATTERY status LED, 407744: BATTERY OK LED
4. Battery compartment cap
* To remove the ½” adaptor, pull straight down as shown in diagram below.
Operation
Theory of Operation
407744 聲級校準器可產生 1 KHz 的 94dB 正弦波。 407766 產生 1kHz 的 94dB 和 114dB 正弦波。當聲級計的麥克風插入校準器時,聲級計拾取訊號並以 dB(分貝)為單位顯示訊號。應調整聲級計(如有必要)以盡可能匹配校準器的輸出訊號(見圖)。
程式.
1. 將麥克風插入校準器的麥克風腔體中,如圖所示;確保其完全插入。對於 1/2” 麥克風,請使用 1/2” 麥克風轉接器(隨校準器一起提供)。取下 1” 麥克風的轉接器。
2. 在 407744 上,將功能開關滑至「I」(開機)位置。一旦裝置通電,就會產生校準音。在 407766 上,根據需要將功能開關滑動到 94dB 或 114dB 位置。一旦設定了開關,校準器就會產生訊號。
3. 讀取聲級計的顯示。聲級計的讀數應為 94dB 或 114dB,取決於校準器的設定。如果聲級計與校準器的訊號不符(在規格範圍內),請按照操作部分中的說明進行調整(通常是前面板或側面板旋鈕調整)。請參閱右圖。
4. 將功能開關滑至「關閉」位置,然後取下麥克風。
電池檢查
在 407744 上,將功能開關移至「電池測試」位置來檢查電池狀況。如果電池正常,電池狀態 LED 應亮起。如果不亮,請更換 9V 電池。在 407766 上, 開機/低電量 LED 電池新鮮時會發出明亮的光,電池電量不足時會發出暗淡的光。
更換電池
取下電池盒蓋(如說明部分所示)即可取出兩 (2) 顆 9V 電池。取出電池並更換新的 9V 鹼性電池。更換蓋子。